DHT - Designers & Manufacturers of Heat Transfer Equipment
  HomeContactInd & AppsCust AssembliesNewsStds & CodesGalleryArticlesNational RepsLine Card  
 

Shell & Tube Heat Exchangers

E-Zee Flow Heat Exchanger Engineering Data

Heat Exchangers Nominal Performance

Model Nominal
Capacity


BTU/Hr
Hot Water Flow


gpm
Pressure Drop


psi
Cold Water Flow


gpm
Pressure Drop


psi
Heater
Transfer
Surface

sq. ft.
Weight
EZ-45 45.000 6.1 0.9 40 1.07 1.62 4
EZ-70 70.000 6.6 1.09 45 1.33 2.64 6
EZ-130 130.000 7.2 1.17 53 1.65 3.64 10
EZ-180 180.000 8 0.4 55 1.1 4.70 12
EZ-250 250.000 9.3 0.6 71 1.7 6.80 16
EZ-300 300.000 10.6 0.9 80 2.5 9.00 22
EZ-500 500.000 14.5 1.3 95 3.2 16.80 25
EZ-1000 1,000.000 25.3 2.35 186.5 4.22 21.21 39

 



Standard Materials: 316L Stainless Steel
Maximum allowable Working Pressure: 250 psig
Maximum allowable Working Temperature: 406°F

 
Dimensions
Model A B C D E F G
EZ-45 11 7/8 4 13/16 5 15/16 3 3/16 1 1/2 1 3/4
EZ-70 15 7/8 9 13/16 1 1/2
EZ-130 19 3/4 11 13/16
EZ-180 15 3/16 5 9/16 10 7/8 4 1 9/16 1
EZ-250 20 1/8 15 15/16
EZ-300 25 7/16 21
EZ-500 43 9/16 39 3/8 2 1/4 2
EZ-1000 38 1/8 8 3/4 31 1/4 5 1/2 3 15/16 2 2

Click Below for More Info on Our E-ZEE Flow Heat Exchangers

Sizing Guide - Engineering Data - Installation Diagram - Warranty Information

 


Diversified Heat Transfer Inc.
, 1710 Flushing Avenue, Ridgewood, New York 11385
Tel: 800-221-1522 / 718-386-6666 Fax: 718-386-7809 Web: www.DHTNET.com